Electrical connection
Electrical connection if using an
external blower
If using the external blower, install a
connection cable between the
ventilation system and the external
blower.
Please follow the Operating and
Installation Instructions for the
DAG 1000.
^ Additional housing knock-outs should
be used for the external blower
housing.
^ Install a suitable UL listed cable
clamp or conduit fitting into the
knock-out.
38
^ Connect to the power supply as
described previously.
^ The external blower will be
connected to the additional control
cable.
^ Close the terminal box.
^ Turn the power supply back on.
Maximum load
with interior-mounted
DAG 500 vent motor . . . . . . . . . . 420 W
with exterior-mounted
DAG 1000 vent motor . . . . . . . . . 210 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit Rating . . . . . . . . . . . . . . . . . 15 A