Installation

DDG 102

The DDG 102 is designed for
installation on angled tiled, pantiled,
slate or shingle roofs. The slope of the
roof must be at least 22° to prevent the
ingress of the elements, such as rain or
snow.
Consult a roofing expert for advice
regarding other types of roofing.
This motor unit is not suitable for
installation on a flat roof.
Installation must only be carried out
by a qualified and competent person.
The external motor is connected to the
cooker hood by means of a control
cable and is operated by the controls
on the cooker hood.
14
Please refer to the operating and
installation instructions for the
cooker hood before installing the
external motor and ducting.
The ducting collar on the motor unit has
a diameter of 125 mm when the
appliance is supplied.
 If a diameter of 150 mm is required,
the front ring of the collar must be cut
at the join with a sharp knife.