External fan version
Depending on the model involved, ex-
ternal fans can be installed on an out-
side wall, on a pitched roof or in a suit-
able location indoors.
– For installation on a pitched roof,
consult the roof tiler beforehand.
– Installation on an outside wall:
First unscrew the sheet metal screws
attached to the sides then remove
the housing case.
Fit the flexible hose or exhaust duct
on to the suction socket, and feed
through a prepared opening in the
wall, together with the power cable,
and make connection with the hood.
Then fix the fan to the wall.
Put back the housing case and se-
cure with the sheet metal screws.
– Installation in an outside wall
Make a hole in the external wall as di-
rected in the installation instructions
for the wall fan.
Remove the four fixing screws and
take off the housing lid. Mark where
the holes for the screws are to be
drilled. Then drill the holes and insert
plugs.
Screw the housing together.
Position the interior telescopic part
and insert foam into the intervening
space. Secure the stainless steel lid
to the housing.
Fit the extraction flexible hose and
connect the control cable connec-
tors together, (if an extension is
needed use the connection cable
supplied).
– Other suitable location
These fan units can be installed at
any suitable location indoors and se-
cured by means of the four holes
drilled in the base plate. Connection
to the hood as well as any possible
extension behind the fan unit is like-
wise made via a flexible hose or ex-
haust duct.
Electrical connection is made by a
power cable connecting the fan and
the cooker hood, thus allowing the fan
to operate at four different settings.
Separate fitting instructions are sup-
plied with the external fan.
27