Due to the higher air flow rates, the exhaust ducting must be laid in such a way that air
flow is not hindered (few bends, short pipelines, well-made connections and transitions
checked for air-tightness). No filters or louvres may be fitted in the exhaust ducting.
The end of ducting leading into the open should be protected against the elements, e.g.,
with a downward facing 90° bend.
 During tumble dryer operation, the room must be adequately ventilated.

Room ventilation opening for air intake from the setup room

The minimum dimension of the ventilation opening depends on the cross-section of the
vent pipe.
If the tumble dryer is connected to a central air supply, additional ventilation openings are
normally not needed.
6" (150 mm)
-
6" (150 mm)
7 1/16" (180 mm)
-
7 1/16" (180 mm)
7 7/8" (200 mm)
-
7 7/8" (200 mm)
8 11/16" (220 mm)
-
8 11/16" (220 mm)
9 13/16" (250 mm)
-
9 13/16" (250 mm)
11 3/16" (300 mm)
-
11 3/16" (300 mm)
Table 3

Supply connection for tumble dryers with a central fresh air intake

For steam-heated tumble dryers, having a central fresh air supply reduces lint build-up
around the heater bank.
 Removing the protective cover exposes live parts.
Any work on the appliance may only be carried out by qualified personnel while the
power is switched off.
For safety reasons, a plastic or steel pipe must be installed from the tumble dryer's central
fresh air intake over a minimum length of 3 ft. (900 mm). Each joint must be secured with
two screws. The supply air pipe must not extend into the tumble dryer.
Supply air, exhaust, and ventilation cross-sections
Vent pipe
A
-
27 7/16"² (177 cm²)
34 7/8"² (225 cm²)
-
39 3/8"² (254 cm²)
50 1/4"² (324 cm²)
-
48 11/16"² (314 cm²)
62"² (400 cm²)
-
58 7/8"² (380 cm²)
75"² (484 cm²)
-
76 1/8"² (491 cm²)
96 7/8"² (625 cm²)
-
109 9/16"² (707 cm²)
139 1/2"² (900 cm²)
Minimum dimension for ventilation opening
A
82 5/16"² (531 cm²)
10 1/4" (260 mm)
104 5/8"² (675 cm²)
11 5/8" (295 mm)
118 1/8"² (762 cm²)
12 3/8" (315 mm)
150 11/16"² (972 cm²)
146"² (942 cm²)
13 3/4" (350 mm)
186"² (1,200 cm²)
15 9/16" (395 mm)
176 11/16"² (1,140 cm²)
225 1/16"² (1,452 cm²)
16 15/16" (430 mm)
228 5/16"² (1,473 cm²)
17 1/8" (435 mm)
290 5/8"² (1,875 cm²)
19 5/16" (490 mm)
328 3/4"² (2,121 cm²)
20 1/2" (520 mm)
418 1/2"² (2,700 cm²)
23 1/4" (590 mm)
9 1/16" (230 mm)
10 1/4" (260 mm)
11" (280 mm)
14" (355 mm)
12 3/8" (315 mm)
12 3/16" (310 mm)
13 3/4" (350 mm)
15" (381 mm)
14 13/16" (377 mm)
15 1/16" (382 mm)
15 3/16" (385 mm)
17 1/8" (435 mm)
18 1/8" (460 mm)
20 1/2" (520 mm)
7