Equipotential
Connection with male thread
bonding
with washers and nut.
Accessories not included (except with offshore version).
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Peak load energy
Control contact voltage
management
Connection cable, min. cross-section
Connection cable (to be ordered separately)
Connection via a flexible supply lead with a separate isolator
is recommended. The isolator should be visible and easily
accessible after machine installation.
Vented
Max. nominal air flow in vented mode (PT 8807 only)
Nominal air flow (PT 8803/8805 only)
Max. permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Alternative connection: Ducted air intake (from outside
building)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm long and secured using two screws.
Fittings (supplied) Without plinth
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Installationsplan / Installation plan: PT 8803/8805/8807
Datum / Date: 12.01.2011
Unobstructed air intake into room recommended (corres-
ponding to 3 times the vent cross-section of machine)
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
mm
10 × 35
M
10
V
AC 230
mm²
5 × 1.5
m³/h
1100
m³/h
1000
Pa
300
mm
150
mm
150
°C
80
cm²
531
mm
161
mm
160
mm
6 × 40
mm
10 × 50
mm
6 × 40
mm
10 × 50
Seite / Page: 10