Miele F 1471 SF Instrukcja obsługi i instalacji - Strona 24
Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Lodówka Miele F 1471 SF. Miele F 1471 SF 29 stron. Product and cut-out dimensions 72" side by side combination
Również dla Miele F 1471 SF: Instrukcja instalacji (24 strony), Wymiary (2 strony)
All plumbing work should be carried
out by a suitably qualified and
competent person, in accordance
with all applicable local and national
regulations.
The water quality must conform to
country requirements for drinking
water.
– The appliance is only suitable for
connection to the cold water supply.
– The water pressure must be between
25 and 120 psi (1.72-8.25 bar).
– A separate shut-off valve must be
installed, so that the water supply
can be interrupted as needed.
– The maximum outer diameter of the
water pipe (without fittings):
3
/
" (10 mm).
8
The shut-off valve for the water
connection must not be located
behind the appliance. It is
recommended to place the shut-off
valve directly next to the appliance
(base unit) or in another easily
accessible location.
Plumbing
71