All electrical work should be carried
out by a suitably qualified and
competent person in strict
accordance with current local and
national safety regulations (BS 7671
in the UK).
If the connection cable is damaged,
it must be replaced by a suitably
qualified electrician with a specialist
connection cable of type H 05 V V-F
(pvc insulated), available from the
Miele Service Department.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held liable for
unauthorised work.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out.
The appliance must only be
operated when built-in. This is to
ensure that all electrical parts are
shielded. Live parts must not be
exposed.
Do not connect the appliance to the
mains electricity supply by an
extension lead. These do not
guarantee the required safety of the
appliance.
Please make sure that the connection
data quoted on the data plate match
the household mains supply.

Electrical connection

Connection should be made via a
suitable isolator or a double pole fused
spur connection unit which complies
with national and local safety
regulations and the on/off switch should
be easily accessible after the appliance
has been built in.
If the switch is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a suitable residual current device
(RCD).
When switched off there must be an
all-pole contact gap of at least 3 mm in
the isolator switch (including switch,
fuses and relays).
Important U.K.
The appliance is supplied for
connection to a 230-240 V, 50 Hz
supply with a 3-core cable.
The wires in the mains lead are
coloured in accordance with the
following code:
Green/yellow = earth
Blue
= neutral
Brown
= live
WARNING
THIS APPLIANCE MUST BE
EARTHED
43