Description
The IUPITER chargers are battery chargers built in primary technology with
wide-range input and active PFC. The devices are built in protection class II
version. They provide a constant direct voltage and direct current with little
ripple. The charger is housed in an aluminum enclosure.
The battery output is short-circuit proof and equipped with an overvoltage and
reverse polarity protection. The battery is separated from the charge control-
ler and protected by a fuse. The charger disposes of a potential-free contact
as immobilizer system for onboard applications e.g. in cleaning machines.
Several internal sensors for temperature control have been installed in the
device. In the case of too high temperatures the charging current is reduced
or the charging process is canceled.
The charging process is displayed by means of a bicolor LED.
EN
Indicating elements
Display
Description
LED ORANGE
Switching on / self test.
briefly flashes
During the self test when switching on
the charger LED briefly flashes orange.
LED GREEN
Charging
flashes
The battery is charged with nominal
current. The LED flashes green until the
battery is charged by approx. 90%.
LED GREEN
Charging process completed
illuminates
The battery is charged by 100% and the
charger is in the trickle charging.
LED RED
Failure / malfunction
flashes
An error has occured before charging
was started.
> See chapter «Troubleshooting».
LED RED
An error has occurred during charging.
illuminates
> See chapter «Troubleshooting».
LED ORANGE
Critical failure / malfunction
illuminated
A critical electronics or software error
has occured.
> See chapter »Troubleshooting«.