Burkert 0344 Instrukcja obsługi - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Jednostka sterująca Burkert 0344. Burkert 0344 14 stron. 3/2-way solenoid valve

Burkert 0344 Instrukcja obsługi
5
INSTALLATION

5.1 Safety instructions

DANGER!
Risk of injury from high pressure in the equipment!
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
WARNING!
Risk of injury from improper installation!
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.

5.2 Before installation

Installation position:
any, actuator preferably upwards.
Procedure:
Check pipelines for dirt and clean.
Install a dirt filter before the valve inlet (≤ 500 µm).
5.3 Installation
NOTE!
Caution risk of breakage!
• Do not use the coil as a lifting arm.
Hold the device with a open-end wrench on the body and screw
into the pipeline.
Valve body must not be installed under tension.
Observe pin assignment according to switching function and
identification.