Alloy Network Device BWS-136 Podręcznik użytkownika - Strona 16
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Konwerter mediów Alloy Network Device BWS-136. Alloy Network Device BWS-136 18 stron. Alloy computer products network device user manual
G
S
OT : Timeout
G
S
OL : Data Length
Access
G
S
OF :IP Filtering
Control
G
S
OI : Authorized IP
TCP Server
G
S
VP : Listen Port
TCP Client
G
S
CI : Destination IP
G
S
CP : Destination Port
G
S
CC : Connection
Logic
System
S
YC : System mode
S
EI : Exit console
DIO
S
DM: Set Digital I/O
mode
BWS-136 User Manual_amend.doc
e.g. $SOS0D0A (CR/LF)
0~65535
(unit: ms)
e.g. $SOT500
0~1024
e.g. $SOL20
0 : Disable
1 :Enable
e.g. $SOI192.168.16.1:192.1
68.16.9 (Starting IP:Ended
IP)
1~65535
e.g. $SVP4000
e.g. $SCI192.168.16.200
e.g. $SCP4001
0 : Reserved for PPPoE
1 :Establish connection when
Serial Data in
R : Reboot system
F : Reset to default setting
and reboot
D : Set current setting as
Default setting
I Input O Output
H pull high, L pull low
- 31 -
G
DM:
Get
I/O mode
G
DI: Get DI channel
status
Remark: Italic font stands for Command String
CR/LF (two bytes)
Both command from host and echo from
:
BWS-136 are terminated with a Carriage Return (ACSII code Hex
0d) and Line Feed (ASCII code Hex 0a). Therefore please
remember to add CR/LF at the end of command line in the terminal
emulation program.
All command strings are in Upper Case
BWS-136 User Manual_amend.doc
e.g. $SDMI:0,4,5
set DIO0, DIO4, DIO5 as
input
$SDMO:1,H,2,L,4,H,7,L
set DIO1 high ,DIO2 low,
DIO4 high, DIO7 low as
Output
Digital
e.g. $GDM
the response is
%GDM I,O,O,O,I,I,O,O
e.g. $GDI
the response is
%GDI 0=1,4=0,5=1
It stands for
DIO0=1,DIO4=0,DIO5=1
- 32 -