SAFETY & TIPS
WARNING
DO NOT CONNECT 24V DC TAPE LIGHTS DIRECTLY TO 120V AC POWER.
•
Tape light should ONLY be powered by a UL Listed Class 2 DC 24V power supply.
•
ALWAYS install in accordance with local and national electrical codes.
•
This product should be installed and serviced by a qualified, licensed electrician.
•
Do not install the product in a location where the ambient temperature is outside the listed ambient temperature
range of the product. Failure to do so could result in damage to the tape light and may alter the tape light's
operational characteristics.
•
Do not exceed the listed maximum run of the product, which is shown on the product packaging. Each maximum
run requires a dedicated power feed from the driver.
•
Do not overload the 24V DC power supply. Overloading the power supply may cause shorting, overheating, and
possibly fire.
•
Do not stare directly into LED lights when illuminated.
•
Always disconnect the power supply before cutting or connecting tape light.
•
Apply power to test the tape light and connections before mounting.
•
Cut the tape ONLY at the designated cut points, indicated by a black mark.
•
The product should be powered by an isolated 24V DC constant voltage power supply with <5% ripple wave.
•
Before permanently connecting tape light sections in a series, the polarity should be tested.
•
Be sure to connect the positive and negative wires from the power supply to the matching poles on the tape light to
avoid damage.
•
Only 80% of the power supply's rated power should be used, in order to guarantee that sufficient voltage is available
to drive the tape.
•
To ensure the longevity and reliability of the tape light, do not bend the tape in an arc with a diameter less than 2.36
inches (see below).