Start-up
The start-up may only be carried out by a qualified electrician.
The safety instructions must be followed during the start-up procedure. See the
safety instructions on the first pages of the appropriate hardware manual.
Check the installation.
Check that the I/O connections have been made as shown in
By default, the regen supply module starts modulating when the power is switched on
unless prevented by I/O.
Switch the power on.
When the regen supply module is modulating, the lower
segments in the 7-segment display are lit in a clockwise-
rotating sequence.
The regen supply module fetches the network data
automatically in the first start-up after the power-up. The
automatic network identification takes 5...10 ms.
In a unit with an externally powered JCU, the automatic
network identification also takes place in the first start-up after
the PU has been switched off.
See the Firmware Manual.
Quick installation and start-up guide – ACSM1-204 11
Safety
I/O connections
Power up
Network identification
Fieldbus control
Default I/O connection
diagram.
7-segment display:
->