Miller 029015507 Instrukcja obsługi - Strona 14
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System spawania Miller 029015507. Miller 029015507 40 stron.
3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
3-2. Unit Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-14 and 4-15 for information on
connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 1045F ( 405C).
Input
Rated
Voltage
Power
Output
Range in
CV Mode
3-Phase
350 A at 34
10−38 V
VDC, 60%
Duty Cycle
*See Section 3-5 for Duty Cycle Rating.
3-3. Dimensions And Weight
.
Overall dimensions (A, B, and C) include lifting eye, handles, hardware, etc.
A. Welding Power Source
Dimensions
A
597 mm (23.5 in.)
B
349 mm (13−3/4 in.)
C
560 mm (22 in.)
D
521 mm (20.5 in.)
E
25.3 mm (1 in.)
F
298.5 mm (11−3/4 in.)
G
12.7 mm (0.5 in.)
Weight
52.5 kg (115.7 lb)
B. Welding Power Source With Cart And Cooler
Dimensions
A
1510 mm (59.5 in.)
B
810 mm (31.9 in.)
C
1110 mm (43.7 in.)
Weight
130 kg (287 lb)
OM-274462 Page 8
SECTION 3 − SPECIFICATIONS
Amperage
Max.
Range in
Open-
CC Mode
Circuit
Voltage
5−425 A
75 VDC
RMS Amps Input at Rated Load Output,
50/60 Hz 3-Phase at NEMA Load Voltages and
Class I Rating
230 V
380 V
400 V
36.1
22.3
20.6
KVA
KW
460 V
17.8
14.2
13.6
956172246_3-A