3-3. Volt-Ampere Curve
3-4. Installing Work Clamp
OM-1321 Page 10
1
2
3
1
Normal Volt-Ampere Curves
The volt-ampere curves show the
normal minimum and maximum
voltage and amperage output capa-
bilities of the welding power source.
Curves of other settings fall be-
tween the curves shown.
185 560
1
Work Cable
2
Boot
Route cable through front panel
opening. Slide boot onto work
cable.
3
Negative (−) Output Terminal
Connect cable to terminal and
cover connection with boot.
Close door.
Tools Needed:
3/4 in
802 515-B