Miller Axcess 675 Instrukcja obsługi - Strona 18
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System spawania Miller Axcess 675. Miller Axcess 675 48 stron. Automatic welding interface and arc welding power source
Również dla Miller Axcess 675: Instrukcja obsługi (48 strony)
4-4. Rear Panel Receptacles And Supplementary Protectors
2
3
4-5. Connecting To Weld Terminals
1
2
Tools Needed:
3/4 in. (19 mm)
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your
machine.
Determine total cable length in weld circuit
(both positive
and
negative
combined)
and
maximum
amperes. See Section 5-1 to select proper
OM-217 751 Page 14
4
6
3
4
5
Correct Installation
cable size.
1
Positive (+) Weld Output Terminal
2
Negative (−) Weld Output Terminal
Connect positive weld cable to Positive (+)
weld terminal and negative (−) cable to
Negative weld terminal.
3
Weld Output Terminal
cables
4
Supplied Weld Output Terminal Nut
welding
5
Weld Cable Terminal
1
.
If using an electrode negative (straight polarity)
process, the volt sense lead must be connected
to the work.
Do not place
anything
between weld
cable terminal
and copper bar.
6
Remove supplied nut from weld output
terminal. Slide weld cable terminal onto
weld output terminal and secure with nut so
that weld cable terminal is tight against
copper bar. Do not place anything
between weld cable terminal and copper
bar. Make sure that the surfaces of the
weld cable terminal and copper bar are
clean.
1
115 V 10 A AC Receptacle RC2
Receptacle
supplies
60
single-phase power. Maximum output
from RC2 is limited by supplementary
protector CB1 to 10 amps.
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects 115 volt receptacle RC2
from overload. If CB1 opens, RC2 does
not work.
CB2 protects the wirefeed motor from
overload. If CB2 opens, the wirefeeder
does not work.
.
Press button to reset breaker. If
breaker continue to open, contact a
Factory Authorized Service Agent.
4
Network Wire Feeder Receptacle
RC1
Use receptacle to connect network
feeder cable to power source (see
Section 4-3).
Ref. 803 823-A
Incorrect Installation
Ref. 803 822-A / 803 778-A
Copper Bar
Hz