Sensor Installation
1. Attach one of the supplied Temperature Sensors to the
Temperature & Pressure Relief Valve (T&P Valve) on the
water heater using one of the supplied Cable Ties. Wrap the
Cable Tie around the T&P valve and then slide the narrow
end of the tie through the slot. Position the tip of the
Temperature Sensor as close to the water heater as possible
and pull the Cable Tie as tight as possible over the bead of
the Temperature Sensor. Ensure that the Temperature
Sensor is in flush contact with the metal body of the T&P
Valve, such that it does not interfere with the operation of
the T&P Valve. Clip off the excess length of the Cable Tie. If
there is another metal plumbing fitting between the T&P
Valve and the water heater, fasten the Temperature Sensor
to that fitting as close to the water heater as possible. Plug
this sensor into the "T&P" connector (the top 2-pin port)
on the side of Aquanta (see Step 4 on page 8).
2. Attach the second Temperature Sensor to the cold water inlet pipe using two of the
supplied Cable Ties. Attachment to four types of water inlet pipes are shown below.
Wrap one of the Cable Ties around the cold water pipe and slide the narrow end