Miller Spectrum Lynx Instrukcja obsługi - Strona 15

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System spawania Miller Spectrum Lynx. Miller Spectrum Lynx 28 stron. Air plasma cutter

2-5. Connecting Work Clamp And Gas/Air Supply

2
3
4
From Gas/Air Supply

2-6. Connecting Input Power

1
2
Rear of Unit
Do not attempt to connect this unit to anything other than a
Miller Bobcat engine-driven welding generator with the proper
conversion kit installed.
1
5
3
4
1
Work Clamp
2
Workpiece
Work clamp cable is attached to
front of unit. Connect work clamp to
a clean, paint-free location on work-
piece, as close to cutting area as
possible.
.
Use only clean, dry air with 90
to 150 psi pressure.
3
Gas/Air Inlet Opening
4
Hose
5
Teflon Tape
Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.
Adjust gas/air pressure according
to Section 3-2.
Tools Needed:
5/8, 1-1/8 in
Ref. ST-801 977
1
Spectrum Lynx
2
Power Plug
3
Bobcat Engine-Driven
Welding Generator With
Required Receptacle Installed
4
AC Power Receptacle For
Lynx
Connect power plug to receptacle
on front of Bobcat engine-driven
welding generator.
ST-801 977 / Ref. ST-802
OM-2219 Page 11
200