Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System spawania Miller XR-S Control. Miller XR-S Control 40 stron. Wire feeder and feeder gun
5-3. Air-Cooled Gun Connections
1
Gun Control Cable
Insert plug into Gun Control receptacle, and
tighten threaded collar.
2
Gun Power Pin
OM-245777 Page 16
Left Side
3
2
1
3
Gun Bushing
4
Gun Securing Knob
5
Drive Casting
4
5
Ref. 246 218-A / 245 945-A / 242 435-A / 151 666-G
Loosen gun securing knob and insert gun
power pin through gun bushing until it
bottoms against drive casting. Tighten
knob.