Miller XT30i Instrukcja obsługi - Strona 30
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla System spawania Miller XT30i. Miller XT30i 44 stron.
7-2. Checking Or Replacing Filter Element
Tools Needed:
5/16 in.
7-3. Checking Shield Cup Shutdown System
OM-256 118 Page 26
.
A complete Parts List is available at www.MillerWelds.com
1
2
3
.
Power must be reset whenever the cup shutdown system
is activated. Always turn Off power when changing or
checking consumables. Do NOT overtighten torch
shield cup. Gently finger tighten cup onto torch.
1
!
Turn
power
Off,
and
disconnect input power plug
from receptacle. Check to
see that all diagnostic LEDs
have
stopped
flashing
before removing wrapper
from unit.
Turn power Off, and disconnect
input power plug from receptacle.
Remove wrapper from unit.
1
Filter Base
2
Filter
3
Filter Cup
Unscrew filter cup from base.
Remove cup.
Unscrew filter element from base.
Check filter element for dirt and
moisture, and replace if necessary.
Be sure that all parts are clean and
dry.
Reinstall filter element, and secure
filter cup.
Reinstall wrapper.
257 595-A / Ref. 805 211-A
4
Torch Shield Cup
Turn Power On and loosen shield
cup. If shutdown system works
properly, Cup light comes on. If not,
immediately turn Off power and
have Factory Authorized Service
Agent check unit.
If system works properly, retighten
cup and reset power.
Ref. 253 554-A