Miller 20 Series Instrukcja obsługi - Strona 19
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria spawalnicze Miller 20 Series. Miller 20 Series 36 stron.
5-4. 14-Pin Plug Information
J
A
K
I
B
N
L
C
H
M
D
G
E
F
*The remaining pins are not used.
5-5. Connecting Welding Gun And Weld Cable
Tools Needed:
9/16, 5/8 in.
Pin*
A
24 volts AC with respect to pin G.
B
Contact closure to A completes 24 volts AC contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts DC output to remote control with respect to pin D.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from remote control with respect to pin D.
F
Current feedback; 0 to 10 volts DC, 1 V/100 A
H
Voltage feedback; 0 to 10 volts DC, 1 V/10 arc volts
7
Pin Information
1
2
3
Loosen knob, insert gun into block.
Position outlet wire guide as close
as possible to drive rolls without
touching. Tighten knob.
4
5
6
7
1
2
3
4
5
6
Ref. S-0004-A
Gun Securing Knob
Gun Block
Gun Outlet Wire Guide
Gun Trigger Plug
Gun Trigger Receptacle
Weld Cable Terminal
Weld Cable From Welding
Power Source
Ref. 281186-A
OM-281138 Page 15