Miller CS310A Instrukcja obsługi - Strona 11

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Latarka Miller CS310A. Miller CS310A 20 stron.

Miller CS310A Instrukcja obsługi

4-4. Remote 6 Receptacle Information For 15 Volts DC

4-5. Remote 14 Receptacle Information For 15 Volts DC

A
J
K
I
B
C L N
H
M
D
G
F
E

4-6. Remote 14 Receptacle Information For 24 Volts AC

A
J
K
I
B
C L N
H
M
D
G
F
E
15 VOLTS DC
OUTPUT
CONTACTOR
REMOTE
OUTPUT
CONTROL
Ref. 805575-A
CHASSIS
15 VOLTS DC
OUTPUT
CONTACTOR
REMOTE
OUTPUT
CONTROL
805497-A
24 VOLTS AC
REMOTE
OUTPUT
CONTROL
Socket
6
1
Contactor control +15 volts DC.
2
Contact closure to 1 completes contactor control
circuit and enables output when Lift-Arc TIG re-
mote is selected.
3
Output to remote control; +10 volts DC output to
remote control.
4
0 to +10 volts DC input command signal from
remote control.
5
Remote control circuit common.
6
Chassis common.
Socket
A
Contactor control +15 volts DC, referenced to G.
B
Contact closure to A completes 15 volts DC
contactor control circuit and enables output.
C
Output to remote control; +10 volts DC output to
remote control.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
*Reconfigurable as input for Output Enable (Weld
Stop) − used to remotely stop the weld outside the
normal welding cycle. Connection to the D socket
must be maintained at all times. If the connection
is broken, output stops, and Auto Stop is dis-
played.
Socket
A
24 volts AC. Protected by supplementary protect-
or CB2.
B
Contact closure to A completes 24 volts AC
contactor control circuit.
C
Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
Socket Information
Socket Information
Socket Information
OM-251981 Page 7