ABB Endura AZ40 Instrukcja obsługi - Strona 12

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Urządzenia przemysłowe ABB Endura AZ40. ABB Endura AZ40 20 stron. Oxygen and carbon monoxide equivalent (coe) analyzer
Również dla ABB Endura AZ40: Instrukcja obsługi (16 strony), Podręcznik (16 strony)

ABB Endura AZ40 Instrukcja obsługi
A.3.5 Sensor signals view – COe signals view page 3
MODBUS address
Description
30068
View 1 – COe concentration
30070
View 2 – COe element temperature difference (°)
30072
View 3 – COe active element temperature (°)
30074
View 4 – COe reference element temperature (°)
30076
View 5 – COe sensor last zero
30078
View 6 – COe sensor last span
30080
View 7 – COe sensor active zero
30082
View 8 – COe sensor active span
A.3.6 Sensor signals view – raw signals view page 4
MODBUS address
Description
30084
View 1 – Oxygen sensor output (mV)
30086
View 2 – Flange block (mV)
30088
View 3 – COe block (mV)
30090
View 4 – Inlet temperature
30092
View 5 – Outlet temperature
30094
View 6 – Transmitter temperature (°)
30096
View 7 – Sensor cold junction temperature (°)
30098
View 8 – Electrical cold junction temperature (°)
A.3.7 Calibration timer
MODBUS address
Description
30100
Calibration progress (% completion)
A.3.8 Analog outputs
MODBUS address
Description
30102
Analog output value (mA) AOUT1
30104
Analog output value (mA) AOUT2
30106
Analog output value (mA) AOUT3
30108
Analog output value (mA) AOUT4
30110
Analog output % of full scale AOUT1
30112
Analog output % of full scale AOUT2
30114
Analog output % of full scale AOUT3
30116
Analog output % of full scale AOUT4
12
COM/AZ40/MOD–EN Rev. A | Endura AZ40 | Oxygen and carbon monoxide equivalent (COe) analyzer
A.4 Read only 32 bits
A.4.1 Transmitter date
Number of seconds since 01/01/2000
MODBUS address
Description
31000
Transmitter – Date of manufacture
A.4.2 Scheduled events
number of seconds since 01/01/2000
MODBUS address
Description
31002
Sensor – Date of manufacture
31004
Scheduled calibration start time
31006
Scheduled blowback start time
31008
Next scheduled calibration time
31010
Next scheduled blowback time
A.5 Read only 16 bits
A.5.1 Sensor hardware version
Valid range 1 to 9.
MODBUS address
Description
32000
Sensor – Hardware version number
A.5.2 Mains voltage
MODBUS address
Description
32001
Mains voltage selection
(0 = Not Set, 1 = 115V, 2 = 230V)
A.6 Read-only 8 bits
A.6.1 Sensor type
MODBUS address
Description
33000
Blowback fitted
33001

Sensor type

33002
Sensor calibration error
A.6.2 Media card version
MODBUS address
Description
33003
Media card percentage full
33004
Media card hardware version number
A.7 Read-only strings
MODBUS address
Description
34000
Transmitter hardware revision number
34002
Transmitter software revision number
34021
Transmitter serial number
34035
Sensor software revision number
34054
Sensor serial number
34069
Media unit software revision number
Definitions
0 = Not Fitted
1 = Continuous
2 = Pulsed
0 = Unrecognized
140 = Oxygen
141 = Oxygen + COe
255 = None
No. of
Bytes
2
19
14
19
15
19