AQUAPHOR B150 FAVORITE Podręcznik użytkownika - Strona 2
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Systemy filtracji wody AQUAPHOR B150 FAVORITE. AQUAPHOR B150 FAVORITE 2 stron.
THE UNIT BOX SHOULD INCLUDE (PCS):
Water filter (housing assembled with the replacement filter cartridge)
Connection node
Ceramic core faucet for clean water (with a set of gaskets as per illustration)
Flexible tube (one metre long)
Flexible tube (one metre long) with a inlet conical bushing
User manual
Packing
INSTALLATION
Determine the best place to mount the faucet (1), water filter (2) and control valve (3).
the tubing should be placed easily and without fracture, and it should be safe of damage and of being pulled out
of the fittings.
NOTE: Use only the faucet provided in set.
Installation of the clean water faucet:
- drill an 11.5-12.0 mm diameter hole in the determined place. Trim burrs;
- screw out the nut (12) off the faucet threaded bushing (1);
- string decorative washer (4) and rubber gasket (5) on the faucet threaded bushing (1);
- install the faucet (1) using washers provided (6; 7; 8) and screw on the nut (9) tight;
- insert the tubing (10) with conical bushing (11) into the faucet threaded bushing (1) and screw on the
nut (12) tight against stop;
- check that all the tubing is connected fully firm.
To connect a water filter to the water supply:
- Shut off the cold water line and discard excess pressure;
- Make sure you have the gasket (3a) in the cap nut
connection node (3);
- Install a pipeline connection node (3). If necessary, to seal
the external thread node, use the tape of sealing material.
Attention: When tightening the nut can not make
significant efforts!
- Close the connection node (to the "valve closed") and by
applying water, make sure to seal joints (no leaks);
- Pull out of the plastic sleeve ball valve connection node (3)
clip (13);
- Insert into the hub node connecting the ball valve (3)
moistened with water pipe (14), be sure to stop bringing it up
to a depth of about 15 mm;
- Insert the clip (13) under a plastic sleeve to connect the ball
valve unit (3);
- Check the strength of the fixing tube (14): 8–10 kgs in an
effort tube (14) should not pull out.
Attaching the flexible tubes to the water filter:
- pull out the clips (13) from-under the plastic bushes of the inlet and outlet connecting pipes of the water
filter (2);
- connect the faucet (2) with the outlet-connecting pipe (15) using the tubing (10).
- connect the control valve (3) with the inlet-connecting pipe (16) using the tubing (14).
The wetted tubing should be inserted against stop at about 15 mm depth.
- insert the clips (13) under the plastic bushes of the inlet and outlet connecting pipes of the water filter (2).
(To disconnect the tubing, remove the clip (13) off the plastic bushing, push the latter on the collar in
and draw the tubing out.)
NOTE: Follow the IN and OUT pointers on the housing lid.
After installation and engaging of the water filter:
- turn on water supply;
1
- turn on the faucet (1);
1
- adjust appropriate water flow, using the control valve (3);
1
- discard the filtred water for 10–15 minutes;
1
- turn off the faucet;
1
- make sure that there is no leakage;
1
- your filter is ready for operation.
1
3
13
3
14
Profile of junction
position
of semi-housings
"valve open"
upper
Household drinking
cold water tap
semi-housing
clamp
bottom
semi-housing
11,5...12 mm
11
12
3a
13
3
Household drinking
cold water tap
14
16
17
18
19
After installation of a new cartridge discard the filtered
water for 10–15 minutes.
1
4
5
6
7
8
9
10
13
15
2
Installation fig.