AQUAPHOR Crystal Solo Podręcznik - Strona 3
Przeglądaj online lub pobierz pdf Podręcznik dla Systemy filtracji wody AQUAPHOR Crystal Solo. AQUAPHOR Crystal Solo 4 stron. Aquaphor crystal solo is an innovative single stage water filter for drinking water purification.
Warning! Don't apply any excessive
force for the screw-tightening while
connecting the shut off valve.
- drill a 12mm diameter hole in the
determined place;
- string decorative support (4), rubber
seal and rubber washer (5) on the
faucet threaded bushing (1);
- screw out the nut (12) off the faucet
threaded bushing (1);
- install the faucet (1) using washers
provided (6; 7; 8) and screw on the
fastening nut (9) tight;
- insert the tubing (10) with conical
bushing (11) into the faucet threaded
bushing (1) and screw on the cap nut
(12) tight against stop;
- insert loose end of tubing into the filter
as 'out' arrow shows. Fix the tubing with
the stopping clip (13);
- lubricate the end of John Guest tube with
water (14) and then insert it into the filter
as 'in' arrow shows, up to the pipe stop
and secure it with the stopping clip (13);
- pull out the stopping clip, insert the
other end of John Guest tube (14) into
shut off valve outlet connection and
then put the stopping clip back (13);
Warning! Lubricated tubes should be
inserted up to the pipe stop to a depth
no less than 15mm. Pull to check that
the connection is secure. It's
important not to confuse 'in' and 'out'
directions of the flow, pay attention to
the arrows on the manifold.
Replacement cartridge installation
- remove the shrink wrap;
- press the locking button, turn the
cartridge counterclockwise, insert a new
cartridge into the system and turn until
you hear the locking button 'click' (fig. 2).
After the filter is installed
- Turn on the cold water line and check
all of the connections for any leaks.
- Open the clean water faucet (1).
- Use shut off valve (3) to adjust water
flow according to the recommended
filtration rate.
- Discard the filtered water for 10
minutes.
- Close the clean water faucet and leave
the filter for 10 minutes.
- Discard the filtered water again for
50 minutes.
- Close the clean water faucet.
- Check all of the connections for any
leaks.
- Your filter is ready for operation.
Cartridge replacement
The filter doesn't need any special treatment
except timely cartridge replacement during
its working lifespan.
- Shut off water supply and open clean
water faucet to dump excess pressure.
- Press and hold the locking button, turn
the cartridge clockwise and then
remove it (fig. 2).
- Remove the shrink wrap from the new
cartridge.
- Insert a new cartridge into the manifold and
turn the cartridge counterclockwise, until
you hear the locking button 'click' (fig. 3).
Rinse the filter according to the "After the
filter is installed" section.
NOTE: If the filter wasn't used for
more than 7 days, discard the filtered
water for 5 minutes.
In case you're not sure about incoming
water bacterial safety, you should boil the
filtered water. Filtered water isn't supposed
to be kept for a long time. Use fresh filtered
water only. Do not expose the water filter to
freezing temperatures. During storage,
transportation and use of the filter protect it
from falls. Do not expose the water filter to
freezing temperatures.
Recycle according to local regulations.
Fig. 2
Fig. 3