14. Troubleshooting
If the appliance has difficulties working, use the Appliance shutoff valve to shut off the incoming water to the
appliance.
Problem
Faucet flow rate is very
slow.
Slow flow rate or no
water from faucet
The storage tank fills
very slowly or does not
fill at all.
If any other faults are identified, please contact our customer service department
at +1 (855) 855 2299 or email [email protected], [email protected]
Possible Cause
Shutoff valve is not
completely opened.
One of the replacement
cartridges needs to be
replaced
How to check if the cartridges lifespan is over.
– Close the shutoff valve and open the faucet in order to release the pressure.
– Replace the cartridges K5, K2, K7M with service caps (located under the lid).
– Open the shutoff valve.
– Open the faucet, flush the water from the unit until the flow rate decreases and
the tank is empty.
If water continues to run faster than 50 ml/min, install the cartridges one at a time
K7М, K2, K5 and according the flow rate decreases determinate which of the
cartridge (or several cartridges) needs to be replaced.
If water runs slower than 50 ml/min, then the membrane needs to be replaced.
Turn off the shutoff valve and open it every time you replace each cartridge
Solution
Open the shutoff valve and faucet completely
Check which cartridge needs to be replaced according
to the resource life, and replace the cartridge.
In order to determine which cartridge needs to be
replaced, please see the instructions below