range from +5 to +38 °C (40 to 100 °F) with intact
packing.
If you have any claims regarding the opera-
tion of your RO, please contact the seller or
manufacturer.
Manufacturer is not responsible for operational
faults occurred due to inappropriate installation
or maintenance.

14. Troubleshooting

If the appliance has difficulties working, use the Appliance shutoff valve to shut off the incoming
water to the appliance.
Problem
Faucet flow rate is very
slow.
Slow flow rate or no
water from faucet
The storage tank fills
very slowly or does not
fill at all.
If any other faults are identified, please contact our customer service department at or email
14
Possible Cause
Shutoff valve is not com-
pletely opened.
One of the replacement
cartridges needs to be
replaced
How to check if the cartridges lifespan is over.
– Close the shutoff valve and open the faucet in order to release the
pressure.
– Replace the cartridges K5, К1, K2, K7M, К7ВМ with service caps (located
under the lid).
– Open the shutoff valve.
– Open the faucet, flush the water from the unit until the flow rate de-
creases and the tank is empty.
If water continues to run faster than 50 ml/min, install the cartridges one at
a time K5, К1, K2, K7М, К7ВМ and according the flow rate decreases deter-
minate which of the cartridge (or several cartridges) needs to be replaced.
If water runs slower than 50 ml/min, then the membrane needs to be
replaced.
Turn off the shutoff valve and open it every time you replace each cartridge
Manufacturer is not responsible for the oper-
ational faults occurred due to inappropriate
replacement cartridges.
Warranty only valid for use in accordance with
instruction and using only unexpired filter car-
tridges. Failure to timely replace filter cartridges
or follow installation or maintenance voids the
warranty.
Solution
Open the shutoff valve and faucet completely
Check which cartridge needs to be replaced accord-
ing to the resource life, and replace the cartridge.
In order to determine which cartridge needs to
be replaced, please see the instructions below