AQUAPHOR CRYSTAL H-80-2 Podręcznik użytkownika - Strona 9

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Fontanna zewnętrzna AQUAPHOR CRYSTAL H-80-2. AQUAPHOR CRYSTAL H-80-2 12 stron. Drinking water fountain

AQUAPHOR CRYSTAL H-80-2 Podręcznik użytkownika
- using boiled water, prepare 2 - 2.5 litres of solution (e.g. 300 g/l) with table salt (do not
use iodized salt);
- place the cartridge with the attached plastic bottle in an upright position (e.g. into a jar).
Direct the plastic tube towards the sink;
- pour the salt solution through the filter, taking care not to let the sediment that remained
during the dissolving of the salt enter the cartridge;
- after the salt solution, pour 2.5 litres of boiled water through the cartridge;
- The cartridge is now ready for use.
Replacing the shut-off valve (18)
If the shut-off valve has signalled a leak and closed the water supply, it should be replaced
in accordance with the following procedure (failure to do so prevents further use of the
water fountain):
- Open the water fountain cabinet door.
- Remove the used shut-off valve.
- Place the valve inside the fountain cabinet in such a way that the safety spring
with litmus paper touches the special gasket at the bottom of the fountain
cabinet (Fig. 8).
- Connect the hose (1) at the valve inlet (marked blue).
- Connect the hose (2) to the valve outlet (marked white).
The inlet/outlet is marked with an arrow on the plastic part of the valve screen (It is
important that the valve handle is in a horizontal position).
AQUAPHOR cartridge wear electronic counter
The timer turns on automatically when water starts flowing through it and turns off 10
seconds after the water stops flowing. By pressing the "SET" button, you can check the
status of the three modes of the counter: the amount remaining until the end of the cartridge
use in litres (litre), water filtration rate (l/m) and the number of days until the end of the
cartridge use in days (day) (Fig. 9 ).
Fig. 9.