3.
5.
INSTRUCTIONS FOR USE
Operating Control Cavity
in the estimated models
During operation, the level of cavity water is re-
corded by a visual display (Fig.10).
The pressure inside the cavity is detected by the
pressure gauge placed on the valve (Fig. 11 C). If it
exceeds kPa 50, the pressure release valve is acti-
vated automatically (Fig. 11 A).
The pressure safety valve can be activated manu-
ally by turning the knob on top of it (Fig. 11 B), thus
decreasing pressure inside the circuit.
During operation, check the level of the water using the visual
display (Fig.10), and bring it to the correct level as needed by
acting on the water filling knobs.
Be careful of the residual risk of being burnt while
topping up the water. Use adequate prevention
and protection equipment.

Deactivation

At the end of the work cycle, turn the burner control knob to
"Zero".
The appliance must be cleaned regularly and
every incrustation or food deposit removed. See
chapter: "Cleaning instructions".
If present, the indicator lights must be off at the
end of the work cycle.
Check the cleanliness and hygiene of the appliance. See
"Cleaning instructions".
Close the network locks upstream the appliance (Gas - Water