TROUBLESHOOTING

Problem
Water Not
Clearing up
UV Lamp indicator
is not lit
No water discharge out of
the filter outlet
No water discharge out of
the waste water outlet
AQP AP2100UV Instructions.indd 14
Reason
Units has not been allowed to run long
enough
Inappropriate pump size
The Pond as a whole is extremely dirty
Fish stocks are too high for system
Filter sponges are dirty
UV Quartz sleeve is dirty
The faint blue glow from the UV globe may
not be visible during bright sunlight hours
Check that the UV Unit has power and the
power point is turned on
The UV globe may be defective
Back flush Knob is pointing towards the
back flush outlet
The pump may not be connected to power
Pond plumbing is blocked
The Inlet and outlet hoses may be on the
wrong way round
The back flush knob has jumped
the cogs in the lid unit
A Q U A T E C E Q U I P M E N T . C O M
Solution
Full effect of the biological cycle has
not been allowed to mature.
This can take up to 8 weeks.
Water flow is too fast for the Biological
cycle settle mature, or the total water flow
is not enough for the for the pond volume.
Remove debits from the pond, for example
stringy algae, leaves, long standing sludge
build-up from the bottom of the pond
Increase filter and pump size
Increase the frequency of filters back
flush and easy cleaning function till water
becomes clearer over time. Some Extreme
situations may require weekly back flushes
Remove and clean as per
cleaning instructions
Wait till evening to check the illumination.
Turn on power
Replace the UV Bulb.
Turn Knob towards the outlet direction
Turn on power
Find blockage & remove
Switch the positions for hoses, such that
the inlet is connected to the correct port
Open up the filter lid and re-alien the cogs
so that the teeth match up correctly
27/10/16 7:53 am