AquaPRO 03AS311 Instrukcja obsługi - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Systemy filtracji wody AquaPRO 03AS311. AquaPRO 03AS311 8 stron. All in one series complete pond and filter system
TROUBLESHOOTING
Problem
Water Pump Not
Working
Water Pump is noisy
UVC Lamp not
working
SPARE PARTS
(NOTE: THESE ARE THE MOST USED)
Low Voltage UV Globe 5W / 9W
Quartz Glass Sleeve
Complete Fountain Kit
12V Transformer 48VA / 72VA
AQP All in One 1000 Instructions.indd 6
Reason
No Power
Sponges and filter media
blocked with sludge
Impellor is blocked with
sludge or limescale
Running without sufficient water
Blocked Impellor chamber or ceramic
shaft is broken
Blockage in pump
Impellor & Shaft worn out
Impellor broken
Water valve closed on the outlet
Unit inlet is blocked or the water
pump inlet is blocked
UVC Globe blown or
Quartz Sleeve broken
Connection of the UVC Globe
not sufficient
Description
Impellor & Shaft
Sponge Filter
A Q U A T E C E Q U I P M E N T . C O M
Solution
Check that the plug is connected
and turned on
Clean the sponges and filters
Clean the Impellor as per
the instructions
Submerse the equipment underwater
then plug in. Refill if necessary.
Clean the Impellor. Check for ware.
Replace if necessary.
Clear the blockage
Replace Impellor & Shaft
Replace Impellor
Open the valve and allow
water to flow
Clear all blockages
Replace as necessary
Push UV Globe in firmly until you
hear a click sound
Model 1000
Model 2000
11AQ110
11A9160
11AU177
11AQ210
11AQ310
11AQ410
04ST048
04ST072
11AQ111
11AQ211
11AQ311
11AQ411
11/7/17 11:35 am