Aquarii Zino Instrukcja instalacji - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Światło powodziowe Aquarii Zino. Aquarii Zino 11 stron. Slope recessed
MOUNTING OPTION
Slope Recessed (Mounting #8)
The parts of the Slope Recessed Mount are labeled as:
• A - Top Cover
• B - Junction Box Cover
• C - Junction Box
• D - Box Assembly
• E - Adjustment Bolts
• F - Extension Rails
• G - Communication Board
• H - Trim Ring
The fixture and mounting option are designed for non-IC (Insulation
Contact) Environments. Ensure insulation is kept away from the
fixture installation location.
Follow the steps below to secure the mount/fixture to the local site.
1. Loosen the four Bolts on the Left/Right Extension Rails and
extend them to the required mounting length, then tighten
the Bolts to secure the Rails in place.
2. Secure the Extension Rails to the sites building structure
using eight screws. See the table below for the
recommended screw parameters based on the present
building material.
WOOD
No. 12 x 2" Zinc-Plated Steel
Screws (3/16" pilot hole)
3. Loosen the Adjustment Nuts to adjust the orientation of the fixture inside the Box Assembly, then tighten the
Adjustment Nuts to secure the fixture in the desired orientation.
4. If a Trim Ring is required proceed to Step 5, if not, then Proceed to the Wiring Connections section of this manual.
5. Obtain the Trim Ring Springs from the separate packaging accompanying the fixture.
6. Secure the first end of the Trim Ring Springs to the Brackets
inside the Box Assembly.
7. Align the holes on Trim Ring so the Springs are completely
vertical.
8. Secure the Springs to the Trim Ring Holes and gently position
the ring against the sites ceiling surface.
9. See the image below for a Rheos installed in a Slope Recessed
Mount.
10. Proceed to the Wiring Connections section on Page 5 of this
manual.
4
CONCRETE
3/16" Dia. X 2 1/4" Blue-
Coated Steel Screws (5/32"
pilot hole)