EQUIPMENT HOOK-UP
Electrical connection
The oven is not provided with power supply cable. When connecting the appliance electrically, an
automatic RCD must be interposed with an opening distance between contacts of at least 3 mm.
connect the appliance electrically it is essential to procede in the following way:
remove the right side panel;
connect to the terminal block the power cable.
The power supply cable must be of H07-RNF type, with approved minimum cross section as prescribed by
the specific directive.
The electrical outlet must be easy to access, no moving should be necessary.
The electrical connection (plug) must be easily accessible, also following oven installation.
!
The distance between the machine and the socket must be adequate to not cause tension in the power
supply cable. In addition, the cable must not be located beneath the machine support base.
If the electrical power supply cable is damaged, it must be replaced by the technical
!
assistance service or by a qualified technician to prevent any risks.
GROUND CONNECTION
It is mandatory that the electrical system is equipped with a ground connection.
The appliance must be part of an equipotential system. The connection is done on terminal marked with
symbol which you will find near the cable clamp. The section of the equipotential wire must be at least
10mm 2
To