Model Number
Item Number
Average Pond Size Recommendation
Maximum Flow Rate
Maximum Head Height
Motor Type
Wattage
Amperage
Power Cord Length
Pump Discharge Diameter
Multi-Hose Fitting Diameters
Warranty
Installation
• Always operate the pump fully submerged. Failure to do so
will overheat the pump and cause it to fail, thus voiding the
warranty. DO NOT OPERATE DRY.
• Use only in fully assembled state, and be sure that both
the upper and lower cage screens are snapped together.
Failure to operate the pump without the fi lter cage closed
will allow large debris to enter the pump, causing the
pump to fail and voiding the warranty.
• Do not wear loose clothing that may become entangled in
the impeller or other moving parts.
• Keep clear of suction and discharge openings. DO NOT
insert fi ngers in pump with power connected.
• Do not pump hazardous materials or liquids, such as oil,
saltwater or organic solvents.
• Do not block or restrict discharge.
• Products returned must be cleaned, sanitized, or
decontaminated, as necessary prior to shipment so as
Typical Installation in an
ecosystem water garden
• The AquaForce
Pump is designed to
®
be submerged directly into the pond.
To maximize pond circulation, locate
the AquaForce
pump as far away as
®
possible from the location of the water
entering back into the water feature.
• It is recommended that the pump NOT
be positioned in the deepest area of
the pond. This will protect the fi sh by
preventing the pond from completely draining in the case
of leak in the plumbing or fi lter. Bricks or stones can be
used, if needed, to raise the pump up off the bottom of the
pond.
4
AQUAFORCE
1000
1800
#91011
#91112
For Ponds up to 2,500
For Ponds up to 3,500
gallons
gallons
1,070 GPH
2,149 GPH
10 ft
16.5 ft
Asynchronous
Asynchronous
55
160
.51
1.33
25 ft
25 ft
1.5" MPT
1.5" MPT
1", 1.25", 1.5", 2"
1", 1.25", 1.5", 2"
3 Year Limited
3 Year Limited
PUMP SPECS
®
2700
#91012
For Ponds up to 5,500
gallons
2,695 GPH
14 ft
Asynchronous
147
1.25
25 ft
1.5" MPT
1", 1.25", 1.5", 2"
3 Year Limited
to ensure that employees will not be exposed to health
hazards in handling said material. All applicable laws and
regulations shall apply.
IMPORTANT: Aquascape, Inc. is not responsible
for losses, injury, or death resulting from a failure
to observe these safety precautions, misuse or
abuse of pumps or equipment.
AQUAFORCE
SPECIFICATIONS
®
• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
• Thermally protected
• This pump has been evaluated for use with fresh water only
• Input Amps & Wattage: See chart on next page
3600
5200
#91113
#91013
For Ponds up to 7,500
For Ponds up to 10,000
gallons
gallons
3,868 GPH
5,284 GPH
18 ft
24 ft
Asynchronous
Asynchronous
215
360
1.8
3
25 ft
25 ft
1.5" MPT
1.5" MPT
1", 1.25", 1.5", 2"
1", 1.25", 1.5", 2"
3 Year Limited
3 Year Limited