AquaScape 91023 Instrukcja obsługi i konserwacji
Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Pompa wodna AquaScape 91023. AquaScape 91023 2 stron. Table top fountain, spitter and statuary submersible pump
Safety infOrmatiOn
WARNING: Risk of electric shock – This pump has not been
approved for use in swimming pool or marine areas.
WARNING: To provide continued protection against risk
of electric shock, connect to properly grounded, ground fault
circuit interrupter (GFCI) outlets only, using the
following guidelines:
(a) Have a qualified electrician install a properly grounded
receptacle outlet, acceptable for outdoor use and protected
from snow and rain.
(b) Inspect cord before using.
(c) Do not use extension cords.
(D) any wiring of pumps should be performed by a qualified
electrician to ensure code compliance and user safety.
(e) unplug pump at receptacle outlet when not
in use or before removal from pond.
(f)
to reduce risk of electrical shock, all wiring
and junction connections should be made per local codes.
requirements may vary depending on usage and location.
(g) the power cable should be protected at all times to avoid
punctures, cuts, bruises and abrasions.
(H) never handle power cords with wet hands.
(I)
Do not remove cord and strain relief. Do not connect
conduit to pump.
(J)
Do not use power cable to lift pump.
inStaLLatiOn
• Always operate the pump fully submerged. Failure to do so will
overheat the pump and cause it to fail, thus voiding the warranty. Do
not oPerate Dry!
• Use only in fully assembled state. Failure to operate the pump without
the cover/strainer in place will allow large debris to enter the pump,
causing the pump to fail, voiding the warranty.
• Do not wear loose clothing that may become entangled in the
impeller or other moving parts.
• Keep clear of suction and discharge openings. DO NOT insert fingers
in pump with power connected.
• Do not pump hazardous materials or liquids, such as oil, saltwater or
organic solvents.
• Products returned must be cleaned, sanitized, or decontaminated, as
necessary, prior to shipment so as to ensure that employees will not be
exposed to health hazards in handling said material. All applicable
laws and regulations shall apply.
ImPORtANt! aquascape, Inc. is not responsible for losses,
injury, or death resulting from a failure to observe these safety
precautions, misuse or abuse of pumps or equipment.
PUmP SPeCifiCatiOnS
• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
• Thermally protected
• This pump has been evaluated for
• Input Amps & Wattage:
use with water only
See Chart Below
WATER PUMP SPECS
Model Number
91023
91024
91025
Maximum Flow Rate
70 GPH
90 GPH
180 GPH
Maximum Head
2.1'
2.8'
4.1'
Height
Motor Type
Mag-Drive
Mag-Drive
Mag-Drive
Wattage
3.0W
4.3W
9.3W
Amperage
0.037
0.061
0.175
Power Cord Length
6'
6'
6'
Discharge Hose
1/2"
1/2"
1/2"
Diameter
tyPiCaL inStaLLatiOn
this pump is designed to be operated
fully submerged in the water feature.
• Select the appropriate fitting(s) needed
for your application.
• Attach tubing to the fitting.
• Connect the other end of the tubing to
the fountain, ornamental spitter or filter.
• Connect the pump to an outlet that is
protected by a ground fault interrupter.
once the pump is running and water
circulating through the filter(s) or
waterfalls, check for any fitting or
waterfall leaks where the external
connections are made.
OPeratiOn and maintenanCe
• Inlet Screen Cleaning -
we recommend inspecting your
pump on a regular basis to
ensure it is functioning properly.
If you notice the water flow rate
diminish, it may be due to the
pump's inlet screen becoming
clogged with debris. In many
cases the clogged screen can
be cleaned by pulling the pump
out of the water to remove
debris from the pump cover. always disconnect the power before
performing maintenance on the pump.
• Internal Pump Cleaning -
If you have thoroughly cleaned
the pump's inlet screen and still
have diminished flow rates,
then you will need to remove
the impeller cover to inspect the
impeller rotor assembly.
• If your rotor assembly impeller
and internal pump body have
excessive scale build-up, clean
with a mild acid, such as
white vinegar or non-abrasive
calcium, lime and rust remover
product using a sponge or soft-
bristled brush that won't scratch
impeller. removing scale build
up will allow your pump to run
like new again.
91026
rePLaCing the imPeLLer aSSembLy
320 GPH
the impeller assembly is the only moving part on the pump and will
5.6'
experience wear and tear. If you've cleaned the pump, as described
above, and still experience poor pump performance, it is most likely time to
Mag-Drive
replace the impeller. replacing the impeller is extremely easy. replacement
Impeller Kits are available through your local Aquascape
17.6W
Winter Storage – The pump can be run during freezing weather, if
0.339
desired, but should be removed if shutting down the pump for the winter.
6'
Disconnect the tubing from the discharge fitting and remove the pump
from the pond. clean the pump and inlet screens with fresh water and
5/8"
store the pump in a frost-free location.
trOUbLeShOOting
• Reduced Water Flow
– Pump or plumbing may be clogged. It may be necessary to clean
the pump intake screen and impeller
Pump Hums and Doesn't Push Water
– Pump or plumbing may be clogged. It may be necessary to clean
the pump intake screen and impeller
– remove the intake screen and impeller cover and inspect and
clean the impeller rotor assembly and internal pump body
– Make sure nothing is blocking or wrapped around the impeller
– Make sure the pump is receiving the correct voltage
Pump Not Working
– the ground-fault circuit-interrupter (gfcI) may have tripped
– the pump is not receiving the correct voltage
dealer.
®
For more information about our company or products,
please visit our website at www.aquascapeinc.com
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426
©2012 Aquascape, Inc.
All Worldwide Rights Reserved
•
I n s t r u c t I o n s & m a I n t e n a n c e
Water
PumP
tabLe tOP fOUntain,
SPitter and StatUary
SUbmerSibLe PUmP
for models:
• 70 GPH (Item #91023)
• 90 GPH (Item #91024)
• 180 GPH (Item #91025)
• 320 GPH (Item #91026)
91027.122011