General Maintenance

• The Aquascape Automatic Dosing System requires minimal maintenance. When replacing water treatments, take a few
seconds to inspect and clean the tubing of any debris that has formed or become trapped in the tubing. A soft pipe
cleaner, available at most hobby stores, can be used to clean the tubing.
• The pump cartridge, located on the underside of the control panel, is a consumable part that may wear over time, reducing
the accuracy of the system. It is recommended to replace the pump cartridge once each year (Pump Cartridge Kit Item#
96040). Please see replacement parts for more information.
• Do not operate at temperatures below 40°F / 4°C as doing so will void the warranty.
PLEASE NOTE: Your Aquascape Automatic Dosing System and liquid water treatments are not designed to
be operated during freezing temperatures. The unit is equipped with an internal protection thermostat that will
shut off the dosing pump at temperatures below 40°F / 4°C. Remove the dosing system during winter freezing
temperatures and store it in a frost free location.

Troubleshooting

• The pump does not seem to be pumping the liquid treatment from the pouch into my pond or fountain.
– Make sure the unit is getting power.
– Make sure the inner tubing and discharge tubing are properly connected and not kinked.
– Make sure the system is primed. To enter the priming mode, hold the x2 dosing button for 3 seconds (this may take
several minutes). Refer to page 5 for more information.
– Listen closely, as you should be able to hear the pump turning if it's working correctly.
– If problems persist, it may be time to replace the pump cartridge.
• There is no power reaching the unit.
– Check that the transformer is plugged in.
– Try replacing the transformer; please note that the Aquascape Automatic Dosing System uses a 12V low voltage outdoor
rated transformer.

Replacement Parts

Automatic Dosing System Replacement Parts
No.
Item number/description
1.
96043 – Output Hose Holder
2.
96044 – O-Ring
3.
96047 – Mounting Plate
4.
96040 – Pump Cartridge Kit
5.
98375 – 6-Watt Transformer
6.
96041 – Tubing Kit
96054 – Control Panel Kit (includes control panel, inner
7.
tubing and discharge tubing)
8.
96045 – Canister
8
Parts List
6
2
8
US (866) 877-6637 |
7
4
1
CAN (866) 766-3426 | aquascapeinc.com
5
3