AquaScape AQUASURGE 4000 Podręcznik - Strona 6
Przeglądaj online lub pobierz pdf Podręcznik dla Pompy do oczek wodnych AquaScape AQUASURGE 4000. AquaScape AQUASURGE 4000 16 stron. Skimmer and pondless waterfall vault pump
Również dla AquaScape AQUASURGE 4000: Instrukcje i konserwacja (16 strony)
General Maintenance
• Filter Screens - Operating the pump without the filter
screen will allow large debris to enter the pump, causing
the pump to fail and voiding the warranty.
• Filter Screen Cleaning - We recommend inspecting your
AquaSurge on a regular basis to make sure it is functioning
properly. If you notice the water flow rate diminish it may
be due to the pump's filter screen becoming clogged with
debris. Always disconnect the power before performing
maintenance on the pump. In many cases the clogged
screen can be cleaned by removing any debris by hand.
If there is a lot of debris and/or the debris is difficult to
clean you may need to disconnect the threaded collar on
the fitting and remove the pump from the filter for a more
thorough cleaning. A garden hose can be used to spray off
any debris stuck on the filter screen. Be sure to replace all
parts including the inner and outer screens, making sure
they are firmly attached to the pump body before lowering
the pump back into the filter box.
• The outer screen can be removed by twisting the locking
knob counterclockwise and pulling the screen off (Ex. 12).
• The inner filter screen is threaded on and can be removed
by unscrewing counterclockwise (Ex. 13).
• Internal Pump Cleaning - If you have thoroughly cleaned
the filter screens on the pump and still have diminished
flow rates, you will need to remove the water cover
chamber (Ex. 14) and inspect the impeller rotor assembly
(Ex. 15).
6
• If your rotor assembly impeller and internal pump body
have excessive scale build-up, clean with mild acid, such
as white vinegar or a non-abrasive calcium, lime and rust
remover product using a sponge or soft-bristled brush that
won't scratch the stainless steel (Ex. 16). Removing scale
buildup will allow your pump to run like new again.
Ex. 12
• When re-assembling the 4000 or 5000 pump models, be
sure to align the raised key on the impeller flange to the
matching notch in the face of the pump flange (Ex. 17).
Ex. 13
Ex. 14
☎
US (866) 877-6637 |
☎
CAN (866) 766-3426 | aquascapeinc.com
Ex. 15
Ex. 16
Ex. 17