ROUTINE MAINTENANCE

Troubleshooting

Red indicator's fixed lighting and shining green light (see 2. Safety general information – knobs and keys
tasks). A different kind of trouble is connected to the green light's frequency and length of time.
Exemple:
GREEN LIGHT
RED LIGHT
Whenever the appliance does not work properly, try to solve the less serious problems using
this table.
TROUBLE
ISSUE
The inductor is not
1
powered
2
High current on the
inductor
High temperature on
3
the cooling unit
High temperature of
4
the cooking area
5
Knob interrupted
High temperature
6
inside the generator
Temperature sensor
7
of the cooking area
10
Connection error
For the all other issues please contact costumer service.
FAULT
The appliance does not turn on
The light indicators do not turn
on.
If the problem cannot be resolved, turn the appliance off and shut all the supply valves. Then
contact customer service.
THE PRESENT MANUAL IS PROPERT Y OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
TROUBLE 06
LONG
1 2 3 4 5 6
FIXED
CAUSE
Improper pot (e.g. aluminium)
Improper pot (e.g. aluminium)
Choked air ducts / Blocked fan
Empty pot
Faulty knob
Obstructed air pipelines/ blo-
cked fan
Sensor short circuit
Connection between control pa-
nel and generator is missing
POSSIBLE CAUSE
The master switch is not connect-
ed. / The residual current device
or circuit breaker has tripped
The master switch is not connect-
ed. / The residual current device
or circuit breaker has tripped
- 14 -
14
LONG
1 2 3 4 5 6
SOLUTION
Use a proper pot (e.g. in 430
steel)
Use a proper pot (e.g. in 430
steel)
Check and free the ducts /
Clean the fan
Remove the pot and turn off
the top
Check / replace switch
Check and free the ducts /
Clean the fan
Check / replace sensor
Disconnect the top from the
supply and check the connec-
tions
INTERVENTION
Connect the master switch.
Restore the residual current de-
vice or circuit breaker
Connect the master switch.
Restore the residual current de-
vice or circuit breaker