AquaStar 32CDBTFR SERIES Instrukcja instalacji - Strona 8
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Sprzęt oświetleniowy AquaStar 32CDBTFR SERIES. AquaStar 32CDBTFR SERIES 20 stron. Channel drain, submerged, suction, single, unblockable outlet instructions
MANUFACTURED SUMP INSTALLATION (BOOSTER & CIRCULATING PUMP INSTALLATION)
IMPORTANT
• Models: 32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Single or multiple drain or pipe use
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
MANUFACTURED SUMP INSTALLATION (DUAL PUMP WITH
HYDROSTATIC VALVE INSTALLATION)
IMPORTANT
• Models: 32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx (AV=Anti-
Vortex)
• Single or multiple drain or pipe use
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
8
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
INTERIOR
POOL FINISH
EARTH
GRAVEL
CIRCULATING PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
Guidelines for Entrapment Hazard.
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
INTERIOR
POOL FINISH
EARTH
GRAVEL
877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
fig. 4
MANUFACTURED
SUMP INSTALLATION
(BOOSTER & CIRCULATING PUMP INSTALLATION)
OPTIONAL HYDROSTATIC VALVE
fig. 5
MANUFACTURED
SUMP INSTALLATION
(DUAL PUMP WITH HYDROSTATIC VALVE INSTALLATION)
PUMP #1
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
FRAME / MUD-RING
SHOTCRETE / GUNITE
BOOSTER PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
OPTIONAL HYDROSTATIC VALVE
FRAME / MUD-RING
SHOTCRETE / GUNITE
PUMP #2
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE