AquaStar 32PD SERIES Instrukcja instalacji - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Sprzęt oświetleniowy AquaStar 32PD SERIES. AquaStar 32PD SERIES 20 stron. Channel drain, submerged, suction, single, unblockable outlet instructions
MANUFACTURED SUMP INSTALLATION (SINGLE PORT / PUMP INSTALLATION)
IMPORTANT
• Models: 32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Single or multiple drain or pipe use
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
MANUFACTURED SUMP INSTALLATION (THREE PORT TEE / SINGLE PUMP INSTALLATION)
IMPORTANT
• Models: 32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
PLUG PORTS NOT BEING USED
INTERIOR
POOL FINISH
EARTH
GRAVEL
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
Guidelines for Entrapment Hazard.
(THREE PORT TEE / SINGLE PUMP INSTALLATION)
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
INTERIOR
POOL FINISH
EARTH
TO PUMP
info
aquastarpoolproducts.com www.aquastarpoolproducts.com
@
fig. 2
MANUFACTURED
SUMP INSTALLATION
(SINGLE PORT / PUMP INSTALLATION)
OPTIONAL SINGLE CONNECTION OR HYDROSTATIC VALVE
TO PUMP
SINGLE PIPE CONNECTION ON
ANY OF THREE PORTS.
1-1/2", 2", 2-1/2", 3" OR GREATER PIPE
fig. 3
MANUFACTURED
SUMP INSTALLATION
GRAVEL
TEE THREE PORTS TOGETHER
1-1/2", 2", 2-1/2", 3" OR GREATER PIPE
FRAME / MUD-RING
SHOTCRETE / GUNITE
FRAME / MUD-RING
SHOTCRETE / GUNITE
7