AQUASTREAM ABSC02782 Instrukcja instalacji, obsługi i konserwacji - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja instalacji, obsługi i konserwacji dla Falownik AQUASTREAM ABSC02782. AQUASTREAM ABSC02782 20 stron.
Models ABSC02787, ABSC02789
(single phase wiring shown)
L, N Ground to be field wired
!
caution
TO AVOID E QUIPME NT DAMAGE
DO NOT CONNE CT POWE R SUPPLY
DIR E CTLY TO HE ATING E LE ME NTS !!!
For illustrative purposes only. Consult with qualified licensed electrician for electrical installation.
Note:
Models ABSC02782
L1, L2, Ground to be field wired
!
caution
TO AVOID E QUIPME NT DAMAGE
DO NOT CONNE CT POWE R SUPPLY
DIR E CTLY TO HE ATING E LE ME NTS !!!
For illustrative purposes only. Consult with qualified licensed electrician for electrical installation.
Note:
Initial Start-Up and Checkout
1. Turn on control. Follow specific instruction sheet provided with controls.
2. Steam will begin to appear within 3-5 minutes at the steam head. Steam will shut offwhen desired tempera-
ture is reached and will automatically resume when room temperature drops below set point.
3. Steam will shut offautomatically when control timer reaches zero. To shut steam offmanually, turn control
OFF. To clear steam from enclosure area, turn shower on before opening door.
4. If unit does not start and control does not turn ON (control display does not light up) then turn breaker off
for twenty seconds and try again.
Maintenance
aq uas team
steambath generators require little maintenance. Other than periodic draining, maintenance pro-
cedures are minimal. E very 2 months, or more often in " hard" water areas, the manual drain valve should be
opened fully flushing out accumulated materials, salts and other particles which are natural by-products of boil-
ing water.
Flush a minimum offi ve hours after the control has been turned offto insure that the water has cooled.
Note:
!
warning
Draining immediately after a steam cycle may expose PVC and other piping to high
temperaturwater. Check local codes. The unit will refill automatically when the control is activated again.
In areas of hard water, a A q u a s t e a m automatic drain valve system is recommended for generator longevity.
8
Residential Steambath Generator Systems
L
N
Knock-out
(fitting omitted
for clarity)
Ground
Ground Lug
(behind probe)
Ground
Power block
L1
L2
Knock-out
(conduit and fittings
omitted for clarity)
Contactor
Ground lug
Fuse
Fuse block
Contactor
aquabrass.com