aquata Dry Diving Suit Podręcznik użytkownika - Strona 16

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Instrument do nurkowania aquata Dry Diving Suit. aquata Dry Diving Suit 20 stron.

SI TECH Suit Inflation Hose with restricted flow
The SI TECH suit Inflation hoses supplied to us, have a flow restriction orifice to make
it easier for less experienced divers to determine their buoyancy. The flow restriction will
also reduce the loss of pressure to the second stage in case the inflator valve should get
stuck open and it will minimize the harm that a free-flowing hose can cause to people
and equipment.
If connected to a first stage with lower, restricting orifice insert in the hose attachment
nipple can be removed to increase the flow.
SI TECH Inflator Valves – maintenance
Avoid exposing the inflator valve quick connector socket to water and Sand. Use the
protective cap when the hose is not attached. Rinse the dry suit and the inflator valve
with fresh water after every dive. After rinsing, attach the hose and blow the valve clean.
If the pushbutton becomes still, spray some silicone into the quick connector socket and
purge. Slide valve: Gently pry the moving activator from the base to apply silicone.
SI TECH Exhaust valves – basic Information
SI TECH exhaust valves are designed to provide two functions:
- As a safety valve (There is no risk of an internal pressure that is harmful to the diver as
the exhaust valve can't be closed entirely).
- As an adjustable overpressure valve
SI TECH exhaust valves are very sensitive to small variations in difference between inter-
nal and external pressure. The exhaust valve is adjustable between 10-200 mm column of
water (100-2000 Pa/0.0145-0.290 PSI) to provide buoyancy variation with the inherent
gas volume.
Adjusting the volume in the suit is hereby simplified and the drysuit may be used as the
only method of buoyancy control during normal diving conditions (BC emptied of air
during the dive). This will support also support a controlled ascent (approximately15 m/
minute) provided the diver's buoyancy is correctly compensated and the valve is trimmed
properly.
Manual deflation: If the pressure setting of the valve is high (clockwise, press anywhe-
re on the valve lid to override this setting and to deflate air. However, the valve is normally
operated by minor pressure changes.
Factors that need to be considered if the deflation capacity of the exhaust valve seems
inadequate are: the valve location on the suit fit (too much volume above the shoulders
could lead to a pocket of air being trapped above the valve), the permeability of the un-
derwear and insufficient weight compensation.
The clicking sound that can be heard when you turn the valve cover makes it
easy for you to fine tune the valve while diving. The Symbols + and – above the
logo label on the lid indicates the effect – (minus) stands for reduced buoyancy
+ (plus) stands for increased buoyancy.
0 7 | EN