Aquatec HydroPro HZ2010 Skrócona instrukcja obsługi - Strona 5

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Pompa wodna Aquatec HydroPro HZ2010. Aquatec HydroPro HZ2010 13 stron. Air pumps

It is also recommended that the air pump should
be at least 6Ft/2m away from the water's edge;
this ensures that there is no intake of moisture.
The air pump is considered weatherproof but must
be mounted above the water level of pond or
water feature at all times. If possible, mount pump
in a cool, shaded location for long-lasting results.
Once the airline is connected onto pump and air
stones are in desired location within the pond or
water feature. Go ahead and locate the two blue
plastic check valves within the box. These check
vales are designed to prevent water from entering
the pump through the airline, in the event that
system is turned off or if pump was to fail.
CLEANING AIR FILTER PAD
IMPORTANT SAFEGUARDS
WARNING: Make sure to unplug power prior to performing maintenance on the air pump or any of its accessories.
We recommend general maintenance of the unit every 3 months (more or less depending on application).
The air filter cartridge on the pump is located on the bottom of pump, near where power cord exits the
pump plastic casing.
The filter pad can get clogged up in time and needs to be cleaned as part of on-going maintenance. It can
easily be removed by flipping the pump over and using a screw driver to pry filter cartridge out of pump
casing, using the little hole in cartridge frame.
A standard household vacuum cleaner is ideal for the suction of dust and debris caught in the air filter
pad or clean in water and make sure to dry completely before re-installation. Filter cartridge is sealed with
an O-ring, make sure not to damage O-ring while disassembling or misplace while cleaning pad.
HPRO Air Pump Z2010_Z4010 Instructions.indd 5
INSTRUCTION MANUAL
NOTE: These one-directional check valves require
installation in the correct direction ("IN"= Inlet
side "OUT"= Outlet side). Install the check valves
on each of the 3/16" airlines, within 1-2ft from the
ports on pump. Simply cut each of the air lines
at desired location and push the check valve into
airline on both sides of valve. Now the installation
is complete and ready for operation!
The air pump is considered weatherproof but
must be mounted above the water level of pond
or water feature at all times. If at all possible,
mount pump in a cool, shaded location for minimal
temperature operation, resulting in long-lasting
results and satisfaction.
V I S I T A Q U A T E C E Q U I P M E N T . C O M
AIR PUMP
22/2/19 11:07 am