System Configuration
Valve Set Up
Model
BACKWASH
565HTO-100
Figure 13. Valve Set Up
Changing Valve Cycle Settings
1. If screen locked, press "
2. Press and hold "
3. Press the "
DOWN" and advance to the BACKWASH menu option. Press " SET/REGEN" to edit the BACKWASH
minutes. Press "
or
accept the new value.
4. Press the "
DOWN" twice to advance to the RINSE menu option. Press " SET/REGEN" to edit the RINSE minutes.
Press "
UP OR DOWN" arrows to change the RINSE minute values. Press " SET/REGEN" again to accept the new
or
value.
5. Press "
MENU" to exit programming mode.
Automatic Bypass
Safety Float
New Sounds
PARAMETER
REGEN. DAYS
BACKWASH
RINSE
Figure 12. Vacation Mode Settings
CYCLE TIME (MINUTES)
BRINE
15.0
90.0
MENU"for three seconds to unlock.
UP AND DOWN" for three seconds to enter Level Two Master Programming.
UP OR DOWN" arrows to change the BACKWASH minute values. Press " SET/REGEN" again to
The regeneration cycle lasts approximately 90 minutes, after which soft water service will be
restored. During regeneration, hard water is automatically bypassed for use in the household. Hot
water should be used as little as possible during this time to prevent hard water from filling the
water heater. This is why automatic regeneration is set for sometime during the night and manual
regenerations should be performed when little or no water will be used in the household.
The brine tank is equipped with a safety float which prevents your brine tank from overfilling as a
result of a malfunction such as a power failure.
You may notice new sounds as your water softener operates. The regeneration cycle lasts
approximately 90 minutes. During this time, you may hear water running intermittently to the
drain.
DESCRIPTION
This value is the frequency of how often the unit should perform a
brief backwash and rinse.
This option controls the length of time in minutes for the unit to
briefly clean the bed by reversing the flow of water upwards through
the bed and out to the drain.
This option controls the length of time to give the tank a brief rinse
from the top to the bottom in order to remove any stale or stagnant
water from the tank.
RINSE
15.0
INJECTOR
REFILL
SIZE
5.0
#2 BLUE
DLFC
BLFC
#3 2.4
#2 0.70
10