HP StorageWorks 8/24 - SAN Switch Uwaga dotycząca wydania - Strona 25
Przeglądaj online lub pobierz pdf Uwaga dotycząca wydania dla Przełącznik HP StorageWorks 8/24 - SAN Switch. HP StorageWorks 8/24 - SAN Switch 32 stron. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
Również dla HP StorageWorks 8/24 - SAN Switch: Specyfikacje (20 strony), Uwaga dotycząca wydania (30 strony), Uwaga dotycząca wydania (29 strony)
Fabric OS 6.1.1b fixes
Table 11
lists defects closed in the Fabric OS 6.1.1b firmware release.
Table 11 Fabric OS 6.1.1b closed defects
Closed defect summary
audicfg is not persistent through hareboot.
HP 4/32B SAN Switch experienced an out-of-memory condition oper-
ating in a fabric with an McDATA 2640 SAN router.
CRC errors were seen on trunk ports between an HP 8/40 and 8/80
switch with a particular SFP type.
GNN_ID query for self NWWN from target results in failure due to
frame reduction logic, causing the Target Port Link to go down, leading
to discovery failures from the host.
A Java out-of-memory condition occurs after WebTools session expired.
Port RSCNs are sent to DPC (VIs and VTs) whenever the configuration
changes, which is unrelated to VI/VT. This affects any application that
uses frame redirect zoning.
With both RD and TI zones configured, a connectivity issue can occur
after hafailover and hareboot.
Frame drop was observed on 4-Gb and 8-Gb switches due to a time
window when a port in a trunk goes offline and the route is not properly
recalculated.
An incorrect status (marginal) occurred when the power cord was un-
plugged.
Unexpected errors encountered during Tape Cancel and Selective
Reset processing during tape creation/restore with FICON tape.
Fabric OS 6.1.1c fixes
Table 12
lists defects closed in the Fabric OS 6.1.1c firmware release.
Table 12 Fabric OS 6.1.1c closed defects
Closed defect summary
If the contents of the /etc/inetd.conf file are modified, the file
may be deleted the next time the switch software is upgraded. User
will not be able to access the switch through the network when this
occurs.
Out of Memory condition on switch occurred in interop mode 2 fabric,
due to memory leak in nsd process, causing hafailover/hareboot to
occur.
Solution
Fixed in Fabric OS 6.1.1b.
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Workaround: Run cfgdisable and
cfgenable commands.
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Solution
Fixed in Fabric OS 6.1.1c.
Fixed in Fabric OS 6.1.1c.
HP StorageWorks Fabric OS 6.1.2b release notes
25