HP StorageWorks 8/8 - SAN Switch Uwaga dotycząca wydania - Strona 39
Przeglądaj online lub pobierz pdf Uwaga dotycząca wydania dla Przełącznik HP StorageWorks 8/8 - SAN Switch. HP StorageWorks 8/8 - SAN Switch 43 stron. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
Również dla HP StorageWorks 8/8 - SAN Switch: Uwaga dotycząca wydania (30 strony), Uwaga dotycząca wydania (29 strony), Uwaga dotycząca wydania (32 strony)
Command ipaddrshow does not show the IP address of a blade that
is seated in slot 12 of an HP StorageWorks DC SAN Backbone Direct-
or.
Re-key of LUNs hosted through active/passive ports will not complete
if started on the passive path.
Wave Length column in port optics dialog is currently blank.
Host may lose targets on edge AG in cascaded setup when failover
from core-AG to another core-AG connected to different edge fabric
switches.
Web Tools zoning breaks when third-party storage virtualization ap-
pliance changed to standby mode.
The removal of an encryption performance upgrade license is not
prevented.
After configuring HP StorageWorks 8/8 or 8/24 SAN Switch AG so
that F-Port Trunking works and then performing portdisable on N-
Ports and then hareboot the 8/8 or 8/24 SAN Switch AG caused
unexpected termination of AGD
Audit Log [ZONE -3001] not generated when a member is added to
TI Zone.
The topologyshow command cannot show the "In ports" mapped
to "Out port" in port-based routing policy.
TCP RX Window advertisement can be much smaller than the actual
size of the RX Window.
FICON Tape Write Pipelining selectively resets after CmdRetry to No
Op Sequence or LBY.
Ficud panic and reboot on HP StorageWorks DC SAN Backbone
Director occurs after executing host command to display the switch.
The event description from swEventTraps (related to RLIR events) is
not well formatted.
Four-node LUN discovery fails if one of the LUN out of 4 LUNs is tres-
passed.
Third-party application paths fails when FC FastWrite is enabled with
bi-directional traffic.
Java running out of memory in Web Tools.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Issue ipaddrshow -slot 12 to get
the information.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable/enable the N_port.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Change the third-party storage virtual-
ization appliance to standby cf mode.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reduce the committed rate on the FCIP
tunnel until the RX window is less than
33 MB.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable FICON Tape Write Pipelin-
ing.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0b release notes
39