HP surestore fc 2Gb entry switch 8B Podręcznik - Strona 18

Przeglądaj online lub pobierz pdf Podręcznik dla Przełącznik HP surestore fc 2Gb entry switch 8B. HP surestore fc 2Gb entry switch 8B 50 stron. Fabric os procedures guide (version 3.0)

2
Basic Configuration Procedures

Upgrading or Restoring the Switch Firmware

To upgrade or restore the switch firmware:
1.
Verify that the RSHD service (on a UNIX machine) or the FTP service (on a Windows
machine) is running on the host workstation.
2.
Login to the switch as the admin user.
3.
At the command line enter the following command:
firmwareDownload "hostIPaddr", "user", "path_filename",
"password"
where hostIPaddr is the IP address of the host computer, user is the User ID used to log
into this computer, path_filename is the path location and filename of the new firmware
file, and password is the password for the user ID specified.
Note:
4.
Reboot the switch by entering the following command:
fastBoot

Disabling a Switch

To disable a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
switchDisable
All Fibre Channel ports on the switch are taken offline, if the switch was part of a fabric, the
remaining switches reconfigure.

Enabling a Switch

To enable a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
switchEnable
All Fibre Channel ports that passed the POST test are enabled. If the switch was part of a
fabric, it rejoins the fabric.
2-4
The password operand is only required if you are using FTP.
Fabric OS Procedures Guide