Display Unit Set Up
7
1.
Insert batteries into the
base of the Display Unit.
Note: Display Unit can alternatively
be powered by a 6V DC supply
The top light will flash as the
Display Unit calibrates and looks
for the Tank Unit. When the Tank
Unit is found the depth will be
displayed on the Display Unit.
8 lights means the tank is full,
2 lights means it is ¼ full.
Level Updates
If Tank Unit Mode Switch is set to 'test mode' – level updates every two seconds.
If Tank Unit Mode Switch is set to 'tank depth' – level updates 3-4 times an hour
(every 15-20 minutes).
LED Lights
The LED lights flash to notify you of any abnormal operating conditions.
(They flash even when the button is not pressed)
Signal has been lost – if this occurs regularly
check range (see next page)
Replace batteries in Tank Unit
Replace batteries in Display Unit
Reset Display Unit (hold down button).
If error persists reset Tank Unit.
If error still persists check range (see next page)
Tank Unit can not detect range due to
something blocking sensor, or the sensor is not
rotated so it is level with the liquid surface
The tank level has dropped very quickly.
Check for leaks. If this occurs without any fluid
loss, this could be a sign that your sensor is not
level to the water.
The tank is almost empty.
The red LED flashes and the Display Unit beeps.
Power Jack 6 Volts DC
300mA or higher
Centre pin positive 2.5mm
Insert 4 x AA batteries
in base of unit