Using WebBrowser
Example of email message sent
If [NORMAL] is selected under [MAIL CONTENTS]
„
If you have completed the email settings
=== Panasonic projector report(CONFIGURE) ===
Projector Type          : LB2
Serial No               : D234567AB 
-----  E-mail setup data -----
TEMPERATURE WARNING SETUP 
MINIMUM TIME           at [ 60] minutes interval 
INPUT AIR TEMPERATURE  Over [ 38C / 100F ] 
ERROR                   [ ON  ] 
LAMP RUNTIME            [ ON  ]   at REMAIN [ 400] H 
LAMP RUNTIME            [ ON  ]   at REMAIN [ 200] H 
INPUT AIR TEMPERATURE   [ ON  ] 
PERIODIC REPORT 
Sunday    [ ON  ]  Monday    [ ON  ]  Tuesday   [ ON  ]  Wednesday [ ON  ] 
Thursday  [ ON  ]  Friday    [ ON  ]  Saturday  [ ON  ] 
00:00  [ ON  ]    01:00  [ ON  ]    02:00  [ ON  ]    03:00  [ ON  ] 
04:00  [ ON  ]    05:00  [ ON  ]    06:00  [ ON  ]    07:00  [ ON  ] 
08:00  [ ON  ]    09:00  [ ON  ]    10:00  [ ON  ]    11:00  [ ON  ] 
12:00  [ ON  ]    13:00  [ ON  ]    14:00  [ ON  ]    15:00  [ ON  ] 
16:00  [ ON  ]    17:00  [ ON  ]    18:00  [ ON  ]    19:00  [ ON  ] 
20:00  [ ON  ]    21:00  [ ON  ]    22:00  [ ON  ]    23:00  [ ON  ] 
-----  check system -----
MAIN CPU BUS                  [   OK   ]
FAN                           [   OK   ]
INPUT AIR TEMPERATURE         [   OK   ]
OUTPUT AIR TEMPERATURE        [   OK   ]
LAMP REMAIN TIME              [   OK   ]
LAMP STATUS                   [   OK   ]
INPUT AIR TEMP.SENSOR         [   OK   ]
OUTPUT AIR TEMP.SENSOR        [   OK   ]
BATTERY                       [   OK   ]
AIR FILTER                    [   OK   ]
(Error code 00 00 00 00 00 00 00 00)
Input air temperature      : 24 degC /  75 degF
Output air temperature     : 26 degC /  78 degF
SET RUNTIME        79 H
LAMP  ON          190 times
LAMP  HIGH          0 H
LAMP  REMAIN     2921 H
-------- Current status ---------
MAIN VERSION         0.22 
NETWORK VERSION      0.01.00 
LAMP STATUS          LAMP=OFF
INPUT SIGNAL         
----- Wired Network configuration -----
DHCP Client  OFF 
IP address   10.69.104.56
MAC address  00:0B:97:41:E3:16
Wed Mar 31 00:53:42 2010
----- Memo -----
lb2
If [SIMPLE] is selected under [MAIL CONTENTS]
„
If you have completed the email settings
Projector Type:
[LB2]
Serial No:
[]
--- E-mail setup data
-TEMP. WARNING SETUP
MINIMUM TIME :
 at [ 60] minutes interval
INPUT AIR TEMP. :
 Over [ 38C / 100F ]
ERROR        [ON ] 
LAMP REMAIN [1000H]
LAMP REMAIN [ 999H]
INPUT TEMP.  [ON ]
-PERIODIC REPORT 
Sun[ON ] Mon[ON ]
Tue[ON ] Wed[ON ]
Thu[ON ] Fri[ON ]
Sat[ON ]
00:00[ON ] 01:00[ON ]
02:00[ON ] 03:00[ON ]
04:00[ON ] 05:00[ON ]
06:00[ON ] 07:00[ON ]
08:00[ON ] 09:00[ON ]
10:00[ON ] 11:00[ON ]
12:00[ON ] 13:00[ON ]
14:00[ON ] 15:00[ON ]
16:00[ON ] 17:00[ON ]
18:00[ON ] 19:00[ON ]
20:00[ON ] 21:00[ON ]
22:00[ON ] 23:00[ON ]
--- check system
FAN    [   OK   ]
LAMP   [   OK   ]
TEMP.  [   OK   ]
FILTER [   OK   ]
OTHER  [   OK   ]
Error code :
 00 00 00 00
 00 00 00 00
--- Tempurature
Input air:
  24 C /  75 F
Output air:
  26 C /  78 F
--- Lamp remain
LAMP     2921 H
----- Memo -----
lb2
(cont.)
15
If an error occurs
=== Panasonic projector report(ERROR) ===
Projector Type          : LB2
Serial No               : D234567AB
 
-----  check system -----
MAIN CPU BUS                  [ FAILED ]
FAN                           [   OK   ]
INPUT AIR TEMPERATURE         [   OK   ]
OUTPUT AIR TEMPERATURE        [   OK   ]
LAMP REMAIN TIME              [   OK   ]
LAMP STATUS                   [   OK   ]
INPUT AIR TEMP.SENSOR         [   OK   ]
OUTPUT AIR TEMP.SENSOR        [   OK   ]
BATTERY                       [   OK   ]
AIR FILTER                    [   OK   ]
(Error code 80 00 00 00 10 00 00 00)
Input air temperature      : 24 degC /  75 degF
Output air temperature     : 26 degC /  78 degF
SET RUNTIME        79 H
LAMP  ON          190 times
LAMP  HIGH          0 H
LAMP  REMAIN     2921 H
-------- Current status ---------
MAIN VERSION         0.22 
NETWORK VERSION      0.01.00 
LAMP STATUS          LAMP=OFF
INPUT SIGNAL         COMPUTER1   ---
                     0.00kHz / 0.00Hz
----- Wired Network configuration -----
DHCP Client  OFF 
IP address   10.69.104.56
MAC address  00:0B:97:41:E3:16
Wed Mar 31 01:28:46 2010
----- Memo -----
lb2
If an error occurs
Projector Type:
[LB2]
Serial No:
[]
--- check system
FAN    [   OK   ]
LAMP   [   OK   ]
TEMP.  [   OK   ]
FILTER [   OK   ]
OTHER  [ FAILED ]
Error code :
 80 00 00 00
 10 00 00 00
--- Tempurature
Input air:
  24 C /  75 F
Output air:
  26 C /  78 F
--- Lamp remain
LAMP     2921 H
----- Memo -----
lb2