DIAQUIP QFS-1200 Instrukcja obsługi - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Piła DIAQUIP QFS-1200. DIAQUIP QFS-1200 12 stron. Electric floor saw

1. PUTTING INTO SERVICE

1.1)
Installation of the diamond saw blade
IMPORTANT: Switch motor off, remove power connection!
The protective hood 12 must be removed and the engine must be put with the pressure switch
05 in its highest position. Important: The fastening is with a left-hand thread on the right side.
A normal right-hand thread is on the left. The two flange parts have to be checked in respect of
cleanness, if necessary they have to be cleaned. When fixing the diamond blade the rotating
direction shown by an arrow has to be observed. The fasting screw has to be tightened
normally with the fork wrench. An excessive tightening is senseless and leads to increased
ware. Now the cover hood 12 mast be mounted and fixed again. The enclosed fork key SW22
matches for the corresponding screws.
Check that the cover hood is firmly mounted and that it the saw not toots
touch the cover hood.
At not right assembly of the diamond saw blade very danger!
You start the engine first after all assembly work is completed completely
Danger
and the protective hood still is placed correctly!
WWW.DIAQUIP.CO.UK
/03