Dibal G300 Series Podręcznik użytkownika - Strona 4

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Wagi Dibal G300 Series. Dibal G300 Series 12 stron.

Dibal G300 Series Podręcznik użytkownika
SERIE G300
1.
Power supply220VAC 12VDC ................................................................ 500mA adaptor (1)
2.
Battery (optional) ........................................................................................... 6VDC 4Ah
3.
Approx. Battery operating time .............................................................................. 100 hours.
4.
Approx. Battery charging time ................................................................................... 8 hours.
5.
Operating temperature ................................................................................... 10ºC to +40ºC.
6.
Weight of scales (battery model) ..............................................................................4.740 kg.
7.
External dimensions : .................................................... 313612cm. With tower: 31x36x36
(1) We recommended only using power supply adaptors supplied by DIBAL S.A.. If for any
reason, a power supply adaptor is used that has not been supplied by DIBAL S.A., it must be
provided with double insulation between the primary and secondary. The scales' guarantee
does not cover damage caused as a result of using parts that are not supplied by DIBAL S.A.
(2) Battery specifications are as follows: lead battery, 6vdc 4.5ah. Use original batteries supplied
by DIBAL S.A. the use of any other type will render the scales' guarantee void and may be
dangerous. The scales' guarantee does not cover damage caused as a result of using batteries
that are not supplied by DIBAL S.A.
See paragraph 2.4.1. Battery operation
2.2.
1.
Range up to 6, 6/15MR, 15, 15/30MR or 30 kg, with a precision to 2, 2/5, 5, 5/10 or 10
grams, respectively (according to model).
2.
Programming of 100 prices of items.
3.
9 direct item keys, permitting access to 18 items.
4.
Possibility of taring up to the maximum range, minus one step.
5.
Choice of different operating modes.
6.
Amount calculated.
7.
RS-232 communications.
1. Use only adaptors and batteries supplied by DIBAL S.A. the use of any other type will
render the scales' guarantee void and may be dangerous.
2. Before using a mains adaptor check the voltage of the adaptor and the corresponding
mains.
3. Make sure that the scales can be connected to a nearby socket that is easy to access. We
recommend that the socket should be provided with differential breaker, thermal-magnetic trips.
If the scales have a battery option, see paragraph 2.4.1. Battery operation.
4. Check that there is no equipment that generates electromagnetic fields (such as
refrigerators, cutting machines, etc.) Connected to the same socket as the scales.
5. Check that the scales are placed on a firm, level surface. The operation of the scale is
sensitive to its levelling and geographic location changes. In case of doubt when changing
the location, consult the manufacturer. Correctly level the scale at its final location, using the
spirit level.
6. Check that no object comes into contact with the dish.
7.
Avoid extreme temperatures. Do not place the scales in direct sunlight or close to air
conditioning vents.
8. These scales have not been designed as waterproof scales. Therefore, avoid high levels of
humidity since this might cause condensation. Protect from rain and avoid direct contact
with water. Do not spray water on the scales or submerge in water. If the scales get wet,
switch off the power supply immediately.

OPERATIONAL AND METROLOGICAL SPECIFICATIONS

2. INTRODUCTION

2.1.

GENERAL SPECIFICATIONS

2.3.

INSTALLING THE SCALES

2
(2)